一、40b工字钢相关参数
40bh=400mm,b=144mm,A=94.07cm2E=2.1×105MPaI=22800cm4,W=1139cm3
型钢抗拉强度标准值:f=210N/mm2二、最大弯矩:Mmax=Wf
2根工字钢组合梁最大抵抗弯矩:
40bMmax=Wf=2×1139cm3×210N/mm2=478380KN·m三、最大剪力:Vmax=fA
2根工字钢组合梁最大抵抗剪力:
40bVmax=fA=2×94.07cm2×210N/mm2=39509.4KN四、悬臂梁端部最大位移:f=ql3/3EI



假定为集中荷载,混凝土自重G=4.95×(1.252.5)×3.2×2450÷2=72765KG=713KN单根工字钢所受总荷载为357KN支点位置(即钢棒位置)距墩身侧面50cm
L=5.5m(荷载作用于端部),40b工字钢:f=ql3/3EI=357×103N×5500mm3÷(3×2.1×105MPa×22800cm4=413mm
L=5m,40b工字钢:f=ql3/3EI=357×103N×(5000mm3÷(3×2.1×105MPa×22800cm4=310mm
L=4.5m,40b工字钢:f=ql3/3EI=357×103N×(4500mm3÷(3×2.1×105MPa×22800cm4=226mm
L=4m,40b工字钢:f=ql3/3EI=357×103N×(4000mm3÷(3×2.1×105MPa×22800cm4=159mm
L=3.5m,40b工字钢:f=ql3/3EI=357×103N×(3500mm3÷(3×

2.1×105MPa×22800cm4=107mm
L=3m,40b工字钢:f=ql3/3EI=357×103N×(3000mm3÷(3×2.1×105MPa×22800cm4=67mm
L=2.5m,40b工字钢:f=ql3/3EI=357×103N×(2500mm3÷(3×2.1×105MPa×22800cm4=39mm
L=1.75m(变截面部分距根部1/4处),40b工字钢:f=ql3/3EI=357×103N×(1750mm3÷(3×2.1×105MPa×22800cm4=13mmL=5.5m,50b工字钢:f=ql3/3EI=357×103N×(5500mm3÷(3×2.1×105MPa×48600cm4=194mm
根据变截面悬臂结构均布荷载转换集中荷载验算时,集中荷载一般作用于距根部1/4处,验算结果240b工字钢梁可以满足施工需要。但施工时,必须对2根工字钢梁进行整体横向连接加固,防止单根工字钢梁在受力时发生扭弯矩。